Liquid level indicator (2 pieces of frame No. 5) art.25.115-2-5
Availability: In stock
The pointer is made to order (7-10 working days)
Wafer distance: 645 mm
Working temperature , no more: 250 °С
Working pressure, no more than: 23 bar
Steel level indicator with flange stopcocks (2 pieces of frame No. 5) art.25.115-2-5
Level indicators art.25.115 have proven themselves well on steam boilers:
- DE series;
- DKVR series ;
- KE series ;
- Viessmann;
- Buderus;
Also, level indicators art.25.115 are installed on other steam boilers, condensate tanks and water storage tanks.
Characteristics
Center distance between flanges: from 590 to 1200 mm.
Working medium - water, water vapor, condensate with pH = 9.5 - 10.5.
Working temperature, no more than - 250 °C .
Nominal pressure: 25 bar
Working pressure, no more than: 23 bar
materials
pos. no. | the name of detail | Qty | Material |
one | Flange Du20, Ru25 | 3 | Steel 3 |
2 | Shut-off valve ARI-Faba art.23.046 | 3 | Ductile iron |
3 | Locking device housing | one | Steel 09G2S |
four | Sealing ring | four | Graphite |
5 | clamp nut | 2 | Steel 09G2S |
6 | Type-setting level indicator frame | one | Steel 09G2S |
7 | Corrugated glass with paronite gaskets | 2 or 3 | Glass / paronite |
Drawing of the level indicator art.25.115 |
Connecting and overall dimensions of level indicators art.25.115
Quantity frames, n | Frame No. | Glass size, mm | L,mm* | Ah, mm | V, mm | Weight, kg |
2 | four | 190*34*17 | 590 | 840 | 2*167 | 27.3 |
2 | 5 | 220*34*17 | 645 | 894 | 2*197 | 28.5 |
2 | 6 | 250*34*17 | 705 | 954 | 2*227 | 29.8 |
2 | 7 | 280*34*17 | 765 | 1014 | 2*257 | 31.3 |
2 | eight | 320*34*17 | 845 | 1094 | 2*297 | 31.8 |
2 | 9 | 340*34*17 | 885 | 1134 | 2*317 | 33.1 |
3 | 6 | 250*34*17 | 890 | 1238 | 3*227 | 35.7 |
3 | 7 | 280*34*17 | 1080 | 1328 | 3*257 | 37.6 |
3 | eight | 320*34*17 | 1200 | 1508 | 3*297 | 38.7 |
* - interaxal dimension L can be changed when ordering (from 590 to 1200mm). It is possible to arrange the frames of level indicators, for example, the use of frame No. 6 and frame No. 8 in one level indicator.
Attention! When ordering a level indicator, you must specify its full designation:
Single level indicator with flange shut-off valves art.25.114-№-L , where:
1) Type-setting level indicator with flange shut-off valves - product name;
2) Art.25.115 - article number of the product;
3) n - the number of frames;
3) No. - the number of frames that are used;
4) L - distance between axes of connecting flanges in millimeters.
If possible, the operating medium, pressure and temperature should also be specified.