Liquid level indicator (frame No. 8) art.16.112-8
Availability: In stock
The pointer is made to order (7-10 working days)
Wafer distance: 520 mm
Working temperature , no more: 180 °C
Working pressure, no more than: 8 bar
Liquid level indicator with threaded stopcocks (frame No. 8) art.16.112-8
Level indicators art.16.112 have proven themselves well on the following steam boilers of the E series:
Also, level indicators art.16.112 are installed on other steam boilers, condensate tanks and water storage tanks.
Characteristics
Center distance between flanges: from 320 to 540 mm.
Working medium - water, water vapor, condensate with pH = 9.5 - 10.5.
Working temperature, no more than - 180 °C .
Nominal pressure: 16 bar
Working pressure, no more than: 8 bar
materials
pos. no. | the name of detail | Qty | Material |
one | Flange Du20, Ru16 | 2 | Steel 3 |
2 | Stainless steel ball valve art.2011 | 3 | Stainless steel |
3 | Locking device housing | one | Steel 09G2S |
four | Level indicator frame art.25.117 | one | Steel 09G2S |
5 | Corrugated glass with paronite gaskets | one | Glass / paronite |
Drawing of the level indicator art.16.112 |
Connecting and overall dimensions of level indicators art.16.112
Frame No. | Glass size, mm | L,mm* | Ah, mm | V, mm | C, mm ** | D,mm | Weight, kg |
2 | 140*34*17 | 320 | 520 | 117 |
85 (105) |
30 (37.5) | 6.7 |
3 | 160*34*17 | 360 | 570 | 137 | 7.1 | ||
four | 190*34*17 | 390 | 600 | 167 | 7.9 | ||
5 | 220*34*17 | 420 | 630 | 197 | 8.6 | ||
6 | 250*34*17 | 435 | 665 | 227 | 9.2 | ||
7 | 280*34*17 | 490 | 700 | 257 | 9.8 | ||
eight | 320*34*17 | 520 | 730 | 297 | 10.2 | ||
9 | 340*34*17 | 540 | 750 | 317 | 10.9 |
* - interaxal dimension L can be changed when ordering.
** - the size of the connecting flange 105mm can be changed when ordering.
Attention! When ordering a level indicator, you must specify its full designation:
Level indicator with threaded stopcocks art.16.112-№-L-С , where:
1) Level indicator with threaded shut-off valves - product name;
2) Art.16.112 - article number of the product;
3) № - index frame number;
4) L - distance between the axes of the connecting flanges in millimeters;
5) C - external diameter of the connecting flange in millimeters.
If possible, the operating medium, pressure and temperature should also be specified.